A Father's Empathy, A CTO's Execution
Pioneering active, ungrounded neurorehabilitation for pediatric hypotonia—replacing rigid mechanical immobilization with responsive kinesthetic cueing.

The Personal Origin: A Father's Mission
When my son was diagnosed with Charcot-Marie-Tooth Type 1B (CMT1B), our family faced a daunting neurological reality: a mutation in the myelin protein zero (MPZ) gene that slows peripheral nerve conduction velocity to under 15 m/s, producing a severe 200 ms sensorimotor reflex latency and generalized muscular hypotonia.
Standard clinical orthotics offered only static, rigid plastic corsets and standing frames. While these hold a fragile child artificially upright, they bypass the child's muscular system entirely, causing progressive paraspinal disuse atrophy and sensory learned non-use.
Observing hands-on Dynamic Movement Intervention (DMI) therapy sessions revealed a transformative alternative: children with hypotonia do not need rigid external scaffolding—they need sub-maximal, precisely timed tactile prompts at distal key points. That insight became Active Kinesthetic Cueing (BalanceImpulse): providing ungrounded micro-second torque bursts (<1.5 Nm) that awaken the child's own postural righting reflexes.
From Living Room Insight to MedTech Rigor
Read the unabridged story of how parental dedication, first-principles physics (T = I · α), and automated multi-agent engineering transformed an urgent family need into a validated pediatric medical platform.
- CMT1B 200 ms Sensorimotor Reflex Delay Compensation
- ≤ 1.5 Nm Pediatric Torque Ceiling (Zero Startle Shock)
- 100% Ungrounded Reaction Momentum (No Rigid Bracing)
Balance Bionics & Mitti: The 10-Year Platform
We cleanly decouple our 10-year deep-tech corporate platform from our compassionate pediatric product line.
The Deep-Tech & IP Platform
Balance Bionics is our European deep-tech holding and intellectual property vehicle. It houses our 5 European patent applications (EPO pending), our non-dilutive grant applications (BMBF KMU-innovativ, ZIM, SPRIND, EIC Accelerator), and our 10-year technology-agnostic roadmap scaling ungrounded momentum exchange into adult neurorehabilitation, gait stabilization, and industrial assistive robotics.
- ✓Proprietary reaction-wheel momentum exchange IP portfolio
- ✓Non-dilutive deep-tech funding strategy (TRL 3 to TRL 6)
- ✓Universal architecture for pediatric and adult neuro-recovery
The Pediatric Assistive Wearable
Mitti is our flagship pediatric product brand—engineered with deep parental care for children with muscular hypotonia and peripheral demyelinating neuropathies. Designed as a soft, non-stigmatizing pelvic wearable (<250g capsule), Mitti preserves full body freedom while providing sub-maximal Active Kinesthetic Cueing to stimulate neuroplasticity.
- ✓Pediatric safety envelope: ≤ 1.5 Nm torque, < 50°C thermal limit
- ✓CE MDR Class I/IIa medical device compliance pathway
- ✓Ergonomic magnetic quick-release harness with zero fear factor

Genesis & Active Kinesthetic Cueing
Observing hands-on DMI physical therapy sessions led to a foundational breakthrough: children with hypotonia don't need heavy, rigid exoskeletons — they need gentle, micro-second tactile cues to awaken their own postural reflexes.
Key Deliverables & Milestones
- Formulation of the ungrounded reaction wheel stabilization concept (T = I · α)
- Initial 3D CAD kinematic packaging and modular harness ergonomics
- Establishment of the 12-persona multi-disciplinary AI engineering team
MuJoCo SITL Simulation & Physics Validation
Before physical fabrication, we constructed rigorous multi-body physics simulations in MuJoCo SITL to validate that ungrounded reaction wheels can effectively stabilize pediatric inverted pendulum dynamics within motor electromagnetic saturation limits.
Key Deliverables & Milestones
- Multi-body pediatric biomechanics model with realistic hypotonic compliance
- Electromagnetic motor saturation and inertia sweep verification (Gate 1 sign-off)
- 3-stage graduated failsafe simulation with zero recoil whiplash
High-Inertia Proving Ground & Testbed
Hardware-in-the-Loop testbed validation using high-inertia direct-drive reaction actuators, field-oriented control (FOC), and deterministic firmware loops to stress-test real-world dynamic response, thermal limits, and failsafe timing.
Key Deliverables & Milestones
- High-inertia direct-drive proving ground verification
- Deterministic real-time control (<1ms loop latency)
- Pediatric 1.5 Nm torque governor and <50°C thermal envelope validation
Clinical Trials & CE/MDR Certification
Transition from laboratory proving ground to supervised clinical pilot trials in pediatric therapy centers, accompanied by full EU MDR 2017/745 Class I/IIa regulatory documentation.
Key Deliverables & Milestones
- ISO 14971 Risk Management & IEC 62304 Software Lifecycle Technical Files
- Multi-center clinical pilot evaluation with certified DMI physiotherapists
- Miniaturized <250g wearable hip module with magnetic Poka-Yoke quick-connect harness
AI-Accelerated MedTech Factory & 4-Gate Governance
Balance Bionics pairs human founder direction (CTO Dad) with domain-specialized multidisciplinary engineering across mechatronics, physics simulation, clinical neurology, and medical safety—strictly governed by 4 non-negotiable Decision Gates.
The 4 Non-Negotiable Decision Gates
Formal Quality GovernancePhysical Feasibility
First-principles verification of torque generation and motor physics.
Medical & Thermal Safety
Pediatric physiological protection and fail-safe operation.
Clinical Benefit
Active motor learning and spinal symmetry protection.
Pediatric Usability
Child and family user experience, ergonomics, and Poka-Yoke safety.
Multidisciplinary Engineering Specialists
12 Active DisciplinesProduct Owner (CTO Dad)
Vision, Prioritization & Ultimate Decision Authority
"Evaluate every concept against real-world benefit for affected children today. Reject ideas that don't improve mobility or safety — regardless of technical elegance or commercial hype."
- Target weight < 250g per hip module
- Zero fear factor or discomfort for pediatric user
- Prioritizes immediate real-world daily utility
Embedded Software Engineer
Firmware Architecture & Real-Time Protocols
"Drive battery-efficient, latency-critical, deterministic firmware. Zero blocking calls in control loops, sub-millisecond execution, and fail-safe watchdog supervision."
- Sub-10ms deterministic inter-module synchronization
- Memory-safe real-time signal processing and PID loops
- Deterministic microsecond sensor fusion execution
Mechatronics Engineer
Actuator Hardware, Motors & CAD Design
"Maximize kinetic momentum power density while minimizing weight and envelope. Optimize reaction mass inertia for whisper-quiet, zero-cogging torque transfer."
- Slotless direct-drive reaction wheel integration
- Biocompatible ergonomic pelvic wearable mounts (< 250 g)
- High-efficiency power buffering and isolated bus distribution
Control Systems Engineer
Sensor Fusion, PID & Postural Filters
"Develop and implement filters, models, and control loops to translate raw sensor telemetry into therapeutically useful corrective reactions without overshoot."
- Complementary 6-DoF IMU sensor fusion
- Sawtooth torque shaping with phase-reset
- Anti-windup PID control with deadband filtering
System Physicist
First-Principles Physics & SITL Simulation
"Challenge every concept on first-principles physical feasibility. Verify momentum transfer T = I · α against motor electromagnetic limits in MuJoCo physics models."
- MuJoCo multi-body pediatric inverted pendulum model
- Electromagnetic motor saturation validation
- Clean SITL parameter sweeps with automated logging
Safety Engineer
Failsafe Architecture & Hazard Mitigation
"Question every hardware and software concept for potential hazards. Demand absolute fail-safety and redundant cutoffs. Accept zero residual technical risk for pediatric patients."
- 1.5 Nm pediatric torque hard ceiling (2.0 Nm cutoff)
- Motor surface temperature strictly <50°C
- 3-stage graduated failsafe (200ms/500ms/1000ms)
MDR Regulatory Expert
Medical Device Regulations & Standards Compliance
"Ensure design decisions, material selection (biocompatibility), and software architecture remain certifiable under EU Medical Device Regulation (MDR 2017/745)."
- ISO 14971 Risk Management compliance
- IEC 62304 Software Lifecycle governance
- Biocompatible skin-contact materials classification
DMI Physiotherapist
Dynamic Movement Intervention & Challenge Calibration
"Continuously seek the 'sweet spot' of maximum challenge. Configure system behavior that intervenes only at the last moment, prompting the patient to self-correct posture."
- Translates DMI tactile facilitation into active kinesthetic cues (BalanceImpulse)
- Sub-maximal tactile challenge thresholds
- Distal-to-proximal active trunk core facilitation
Mototherapist
Gait Kinematics & Dynamic Muscular Recruitment
"Treat learning to walk as playful sport. Use dynamic, action-rich stimuli to 'wake up' muscular hypotonia and provide an energetic pace-maker for fluid forward motion."
- Asymmetric sawtooth dithering prevents neural adaptation
- Rhythmic walking metronome synchronization
- Dynamic cadence pacing for fluid locomotion
Kinder-Physiotherapeutin
Pediatric Fatigue & Cardiovascular Protection
"Monitor cardiovascular and muscular load limits precisely. Demand intelligent logic that recognizes exhaustion patterns and throttles the system before overexertion."
- Continuous fatigue monitoring telemetry for all users
- Optional HCM (Hypertrophic Cardiomyopathy) soft-mode throttling
- Overexertion prevention via telemetry thresholds
Pädiatrischer Orthopäde
Spinal Biomechanics & Scoliosis Prevention
"Evaluate all system impulses and harness concepts strictly for biomechanical impact. Block concepts that could cause asymmetric loading or spinal deformity."
- Dual IMU (thoracic vs. pelvic) differential tracking
- Spinal symmetry enforcement in 3D planes
- Eliminates axial compressive loading on pediatric spine
Ergonomie-Designer
Pediatric UX, Harness Ergonomics & Poka-Yoke Design
"Focus on absolutely frictionless, self-explanatory 'plug-and-play' experience. Design physical and digital interaction points so error-resistant (Poka-Yoke) that no manuals are needed."
- Poka-Yoke magnetic quick-release fasteners
- High-contrast clinician touch interface
- Ultra-soft, washable pediatric-grade harness lining
Evidence-Based Pediatric Neuroplasticity
In compliance with our single-home content architecture, the complete biomechanical methodologies (Dynamic Movement Intervention, Vojta Reflex Locomotion, Bobath Tone Regulation, and Assist-as-Needed Control) and our 6 clinical operational modes are maintained centrally on our dedicated clinical portal.
Distal micro-prompts provoke active trunk muscle self-recruitment.
Automatic postural righting circuits and bilateral spinal symmetry.
Sawtooth torque dithering prevents sensory neural habituation.
Explore Research Preprints & Technical Specs
Access our scientific publications, interactive MuJoCo physics simulation sandbox, and formal safety guarantees.
Reaction-Wheel Postural Stabilization
Read our scientific preprint on ungrounded reaction-wheel momentum exchange, CMT1B reflex delay modeling, and Real2Sim SITL verification.
MuJoCo Simulation Demo
Test first-principles reaction torque physics (T = I · α), parameter sweeps, and inverted pendulum stabilization live in browser.
Partner With Balance Bionics & Mitti
We are selecting clinical trial sites, pediatric physiotherapy practices (DMI certified), grant consortia, and mission-aligned deep-tech investors for upcoming pilot study cohorts.
Pediatric motion analysis centers and certified DMI clinicians for active protocol design and longitudinal kinematic tracking.
Academic and clinical research institutions collaborating on BMBF KMU-innovativ, SPRIND, and EIC Accelerator projects.
Caregivers of children with hypotonia or CMT seeking information on future supervised clinical evaluations.